Product Overview

The Single-Phase Hybrid Inverter Series coordinates rooftop PV, a 48 V battery, utility power and backed-up loads in one configurable platform. Five output ratings allow system capacity to follow actual demand. Multiple charging priorities, scheduled charging and discharging, battery-less output capability and remote monitoring support both everyday solar self-consumption and practical outage preparation..
Engineering Features
-
Efficient Energy Conversion
MPPT tracking efficiency reaches 99.9%, while maximum battery inversion efficiency reaches 93%.
-
Four Charging Strategies
Choose Mains Priority, PV Priority, Hybrid Mains & PV or PV Only to suit site conditions.
-
Practical Backup Capability
Battery-less output, independent PV startup with load and battery activation extend operating flexibility.
-
Flexible Parallel Expansion
Up to nine compatible units can be paralleled for higher power and supported phase configurations.
-
Local and Cloud Monitoring
RS485, CAN, USB and dry contact are built in, with optional Wi-Fi or 4G connectivity.
-
Controlled Operation & Maintenance
Protection functions, visible fault information and scheduled operation support routine management.
Choose the Right GST Model
Technical Specifications
Recommended Applications
Residential solar self-consumption
Use daytime PV generation for household loads and store available surplus energy for later consumption.
Essential-load backup
Support selected household, office or retail circuits during utility interruptions when inverter and battery capacity are correctly sized.
Weak-grid and rural systems
Coordinate PV, battery and mains energy where utility supply is unstable or solar energy is the preferred source.
Small commercial and phased projects
Serve controlled commercial loads and reserve the option for later parallel capacity expansion.
Selection Guidance
Continuous and starting loads
Add simultaneous loads and check motor, pump, compressor and air-conditioner startup demand separately.
PV string design
Keep normal operation within 120–450 V and cold-weather open-circuit voltage below 500 V per MPPT.
Battery capability
Verify BMS protocol, charging and discharge-current limits, cable size and DC protective devices.
MPPT and expansion
Use separate MPPT inputs for dissimilar arrays and confirm all parallel-system accessories before ordering.
Installation and Maintenance

- Install in a dry, ventilated indoor location consistent with the IP20 protection level.
- Confirm polarity, PV voltage, battery parameters, cable sizing and AC/DC protection before energizing.
- Keep cooling inlets and outlets clear and maintain the required installation spacing.
- Review alarms, battery communication and PV input values during routine inspection.
- Check terminals for looseness, heat marks or discoloration after safe electrical isolation.
FAQ
Q:Can the inverter operate without a battery?
The series supports battery-less output and independent PV startup with load. A battery remains recommended where dependable backup is required.
Q:Which models provide two MPPT inputs?
GST48-8.5K-P1, GST48-10.5K-P1 and GST48-12.5K-P1 provide two MPPT channels.
Q:Can different lithium battery brands be connected?
Only after voltage, current limits, BMS communication protocol and approved compatibility have been confirmed.
Q:Is this product suitable for outdoor installation?
The inverter is rated IP20 and should be installed in a suitable protected indoor environment with adequate ventilation.
Configure the Right Inverter for Your System
Send the installation country, AC supply, load list, PV module data, battery specification, required backup duration and monitoring requirements. SINELINK can support model review and quotation preparation.
Send Inquiry NowFinal selection must follow the approved model datasheet, battery compatibility information, PV calculation and local electrical requirements. Product data are subject to confirmation before order.