2.56-16.1 KWh Rack-Mounted LiFePO4 Battery

2.56-16.1 KWh Rack-Mounted LiFePO4 Battery

Product: Rack-Mounted LiFePO4 Battery
Models: GBP24-100R / GBP24-200R / GBP48-100R / GBP48-200R / GBP48-314R / GBP51.2-100R / GBP51.2-200R / GBP51.2-314R
Nominal voltage options: 25.6V / 48V / 51.2V
Nominal energy range: 2.56–16.1kWh
Standard charge/discharge rate: 0.5C
Maximum continuous rate: 0.5C for 314Ah models; customizable 1C for other models
Cycle life: 6000+ cycles at 80% DOD
Battery management: Built-in BMS
Communication: RS485 for compatible inverter and monitoring systems
Status indication: LED indicators
Parallel identification: Automatic address assignment without manual dial coding
Installation: Rack-mounted modular configuration
Protection level: IP20
Charging temperature: 0–55°C
Storage temperature: −20–55°C; recommended 10–35°C
Cooling: Natural air cooling / intelligent fan, depending on configuration
Send Inquiry
Description
Technical Parameters
RACK-MOUNTED LITHIUM IRON PHOSPHATE BATTERY
2.56–16.1 kWh
ENERGY RANGE
8 models
RACK OPTIONS
24–51.2 V
VOLTAGE CLASSES
6000+
CYCLES @ 80% DOD
product-1027-1088

Product Overview

 

The series is  compact rack-mounted lithium iron phosphate battery family for solar storage, UPS backup, communication base stations and equipment rooms. Eight models cover 25.6V, 48V and 51.2V platforms from 2.56 to 16.1kWh, with LED status indication, inverter communication and automatic address assignment for parallel systems.

Use identical approved modules and align voltage/SOC before paralleling. Automatic addressing simplifies identification but does not replace protection, current-sharing and commissioning checks.

 

Product Features

  • Compact Rack Format

The integrated modules support structured cabinet installation and efficient use of equipment-room space.

  • Visual Operating Status

LED indicators provide immediate local status visibility, while RS485 can upload battery information in compatible systems.

  • Automatic Address Assignment

Parallel modules can be automatically addressed without manual dial coding, reducing repetitive setup steps during expansion.

  • BMS-supported Operation

The BMS supports balanced management across an approved battery bank to help maintain stable modular operation.

  • Broad Low-voltage Selection

Multiple voltage, capacity and enclosure combinations support differentiated residential, telecom, PV and UPS projects.

Technical Specifications

Model-specific Electrical and Mechanical Data
Parameter
LFP24-100R
LFP24-200R
LFP48-100R
LFP48-200R
LFP48-314R
LFP51.2-100R
LFP51.2-200R
LFP51.2-314R
Nominal voltage (V)
25.6
25.6
48
48
48
51.2
51.2
51.2
Cell specification
100
100
100
100
314
100
100
314
Nominal capacity (Ah)
100
200
100
200
314
100
200
314
Nominal energy (kWh)
2.56
5.12
4.8
9.6
15.07
5.12
10.24
16.1
Operating voltage range (V)
22.4–29.2
22.4–29.2
42–54.75
42–54.75
42–54.75
44.8–58.4
44.8–58.4
44.8–58.4
Recommended charging voltage (V)
27.6
27.6
51.75
51.75
51.75
55.2
55.2
55.2
Recommended discharge cut-off (V)
24
24
45
45
45
48
48
48
Maximum continuous rate
1C customizable
1C customizable
1C customizable
1C customizable
0.5C
1C customizable
1C customizable
0.5C
Dimensions (D×W×H, mm)
689×495×162
689×495×162
689×495×162
682×510×246
904×465×252
689×495×162
682×510×246
904×465×252
Weight (kg)
28
49
46
93
136
49
96
140
Shared Operating Parameters
Standard charge/discharge rate
0.5C
Allowable humidity range
85% RH
Storage temperature
−20 to 55°C; recommended 10 to 35°C
Charging temperature
0 to 55°C
Protection level
IP20
Cooling method
Natural air cooling / intelligent fan
Cycle life
6000+ cycles @ 80% DOD

Specifications are subject to change without prior notice.

Parallel Rack Expansion Basics

Automatic addressing identifies modules; it does not balance energy automatically

Modules should enter the bank at compatible voltage and SOC. Large mismatch can create equalization current before normal load is applied.

Parallel current paths should be symmetrical

Use an approved busbar or equal-length conductor arrangement so cable resistance does not cause one module to carry disproportionate current.

Each voltage class requires matching equipment settings

Do not mix 25.6V, 48V and 51.2V modules. Confirm inverter voltage window, charge setpoint, cut-off and BMS protocol for the selected platform.

Rack layout affects serviceability

Plan module order, isolators, fuses, communication daisy chains and lifting access so a unit can be isolated and removed without disturbing the whole bank.

Automated Production for Consistent Quality

product-900-717
product-900-717

Automated production processes help improve repeatability in battery assembly. Consistent process settings, accurate component positioning and controlled connections support uniform build quality across production batches.

Process control and in-process inspection help identify assembly deviations early, supporting stable product quality and reliable operation in the finished battery system.

Repeatable assembly · Consistent connections · Process quality control

Battery Aging and Charge/Discharge Testing

Controlled aging and charge/discharge cycles help evaluate battery capacity and operating stability under load. Monitoring voltage, current and temperature helps identify abnormal behavior and assess cell consistency.

Battery data, alarm status and communication checks provide additional insight into BMS operation within a matched system.

Capacity evaluation · Thermal monitoring · BMS performance
product-1200-928

Recommended Applications

  • Residential solar storage and backup racks
  • UPS and computer-room standby systems
  • Communication base stations and auxiliary DC systems
  • Small commercial modular energy storage
  • Projects requiring staged capacity expansion

Installation and Maintenance

  • Verify rack loading, fixing, airflow and safe module-handling access.
  • Confirm every module has the same approved voltage platform, firmware and communication configuration.
  • Align module voltage/SOC before making parallel power connections.
  • Use coordinated branch protection and a balanced busbar or equal-resistance cable layout.
  • After automatic addressing, verify module count, addresses, alarms and current sharing.
  • During inspection, review LEDs, communication, terminal temperature, fan condition and rack fasteners.

Packing and Transport

product-1310-1080

Ship each battery in approved protective packaging with terminals insulated against short circuit. Confirm required lithium-battery test summaries, labels, documents, state-of-charge limits and carrier restrictions for the selected transport route. Keep packages upright and dry, protect them from impact, and quarantine any unit showing deformation, leakage, unusual odor or abnormal heat..

FAQ

Can different voltage models be installed in one parallel bank?

No. Select one approved voltage platform and use compatible modules, BMS settings and inverter parameters.

Does automatic addressing eliminate commissioning?

No. Confirm detected module count, address order, alarms, SOC/voltage alignment, communication and current sharing.

Which models have a 0.5C maximum continuous rate?

GBP48-314R and GBP51.2-314R have a maximum continuous rate of 0.5C. The other models offer a customizable 1C configuration.

Can GBP-R batteries be installed outdoors?

The IP20 battery requires a dry, protected installation environment with suitable ventilation and service access.

Configure a Balanced Modular Battery Rack

Contact SINELINK with your inverter or UPS model, voltage platform, required backup duration and rack layout to select a suitable battery configuration.

Send Inquiry Now
Related: Residential Energy Solutions · More Products

Product configuration and supply scope are specified in your quotation.

Hot Tags: 2.56-16.1 kwh rack-mounted lifepo4 battery, China 2.56-16.1 kwh rack-mounted lifepo4 battery manufacturers, suppliers, factory, energy storage systems residential, home battery storage with solar, home energy storage battery, solar panels with battery storage for home

Technical Specifications

Model-specific Electrical and Mechanical Data
Parameter
LFP24-100R
LFP24-200R
LFP48-100R
LFP48-200R
LFP48-314R
LFP51.2-100R
LFP51.2-200R
LFP51.2-314R
Nominal voltage (V)
25.6
25.6
48
48
48
51.2
51.2
51.2
Cell specification
100
100
100
100
314
100
100
314
Nominal capacity (Ah)
100
200
100
200
314
100
200
314
Nominal energy (kWh)
2.56
5.12
4.8
9.6
15.07
5.12
10.24
16.1
Operating voltage range (V)
22.4–29.2
22.4–29.2
42–54.75
42–54.75
42–54.75
44.8–58.4
44.8–58.4
44.8–58.4
Recommended charging voltage (V)
27.6
27.6
51.75
51.75
51.75
55.2
55.2
55.2
Recommended discharge cut-off (V)
24
24
45
45
45
48
48
48
Maximum continuous rate
1C customizable
1C customizable
1C customizable
1C customizable
0.5C
1C customizable
1C customizable
0.5C
Dimensions (D×W×H, mm)
689×495×162
689×495×162
689×495×162
682×510×246
904×465×252
689×495×162
682×510×246
904×465×252
Weight (kg)
28
49
46
93
136
49
96
140
Shared Operating Parameters
Standard charge/discharge rate
0.5C
Allowable humidity range
85% RH
Storage temperature
−20 to 55°C; recommended 10 to 35°C
Charging temperature
0 to 55°C
Protection level
IP20
Cooling method
Natural air cooling / intelligent fan
Cycle life
6000+ cycles @ 80% DOD

Specifications are subject to change without prior notice.

Send Message