Product Features
- Lower installed conductor cost: Aluminium is well suited to long feeders and larger distribution circuits where space permits a larger conductor cross-section.
- Reduced cable weight: The lighter conductor simplifies drum handling, cable pulling and support loading on long routes.
- XLPE insulation: Provides strong electrical properties and supports a 90°C maximum conductor temperature in normal service.
- Protective PVC sheath: Resists normal abrasion, moisture and environmental exposure in fixed installations.
- Broad size range: Single-core sizes extend from 1.5 to 630 mm², with two-core sizes from 1.5 to 185 mm² in the listed range.
- Flexible installation options: Suitable for cable trays, conduits, ducts, shafts, service tunnels and protected underground routes.
Cable Construction
|
Component |
Description |
|
Conductor |
Solid, stranded or compacted aluminium conductor selected according to cable size and applicable conductor class. |
|
Insulation |
Cross-linked polyethylene (XLPE) providing the primary 0.6/1 kV electrical insulation. |
|
Core assembly |
Two insulated conductors assembled into a stable cable core in two-core constructions. |
|
Outer sheath |
PVC sheath providing mechanical and environmental protection for fixed installation. |
|
Cable type |
Unarmoured YJLV construction; external mechanical protection is required where impact or crushing is possible. |
Typical Applications
- Industrial distribution: Feeds switchboards, motor-control centres, workshops and fixed production equipment.
- Commercial buildings: Connects main and sub-distribution boards across long internal service routes.
- Infrastructure projects: Supports power distribution in transport facilities, water plants, warehouses and municipal installations.
- Renewable-energy facilities: Provides AC-side auxiliary and distribution connections for solar and energy-storage projects.
- Utility service routes: Offers a lower-weight conductor solution for ducts, cable tunnels and protected external feeders.
- Large fixed loads: Supplies HVAC equipment, pumps and other stationary loads where the termination system is designed for aluminium conductors.
Selection Guide
- Load current: Use the aluminium-cable ampacity table for the actual installation method. Do not select YJLV using a copper-cable cross-section table.
- Voltage drop: Aluminium has higher resistance than copper at the same cross-section. Long feeders commonly require a larger aluminium conductor.
- Short-circuit withstand: Check conductor thermal withstand against the maximum prospective fault current and protective-device clearing time.
- Installation derating: Apply correction factors for ambient temperature, grouping, conduit, soil conditions and thermal insulation.
- Termination compatibility: Use terminals, lugs and glands rated for aluminium conductors and for the cable's conductor class and shape.
- Mechanical exposure: Standard YJLV is unarmoured. Add conduit, ducts, covers or another protective method where impact, crushing or high tensile load is possible.
- Fire requirements: The standard PVC sheath is not a low-smoke zero-halogen construction. Use a dedicated cable design when LSZH performance is required.
Information to Include with Your Enquiry
- Single-core or two-core construction
- Required conductor size, quantity and route length
- Load current and protective-device rating
- Installation method, ambient temperature and cable grouping
- Allowable voltage drop and prospective short-circuit current
- Terminal or lug type and connected equipment material
- Required drum length, cable marking and sheath colour
- Applicable IEC or GB/T standard and destination marke
A lightweight, cost-efficient aluminium cable for fixed 0.6/1 kV power distribution.
Technical Data
|
Item |
Value |
|
Model designation |
YJLV |
|
Cable type |
Aluminium conductor, XLPE insulated, PVC sheathed, unarmoured power cable |
|
Rated voltage Uo/U |
0.6/1 kV |
|
Maximum conductor temperature |
90°C in normal operation |
|
Short-circuit conductor temperature |
Up to 250°C for a maximum of 5 seconds |
|
Core configurations covered |
Single-core and two-core |
|
Single-core size range |
1.5-630 mm² |
|
Two-core size range |
1.5-185 mm² |
|
Installation |
Fixed installation in trays, conduits, ducts, shafts, tunnels and protected outdoor routes |
|
Reference standards |
IEC 60502-1 / GB/T 12706.1 product options; aluminium conductor requirements based on IEC 60228 |
Single-Core YJLV Dimensions and Weight
|
Conductor size (mm²) |
Insulation (mm) |
Sheath (mm) |
Approx. O.D. (mm) |
Approx. weight (kg/km) |
|
1 x 1.5 |
0.7 |
1.4 |
6 |
38 |
|
1 x 2.5 |
0.7 |
1.4 |
6 |
44 |
|
1 x 4 |
0.7 |
1.4 |
7 |
52 |
|
1 x 6 |
0.7 |
1.4 |
7 |
62 |
|
1 x 10 |
0.7 |
1.4 |
8 |
84 |
|
1 x 16 |
0.7 |
1.4 |
9 |
109 |
|
1 x 25 |
0.9 |
1.4 |
11 |
149 |
|
1 x 35 |
0.9 |
1.4 |
12 |
184 |
|
1 x 50 |
1.0 |
1.4 |
13 |
232 |
|
1 x 70 |
1.1 |
1.4 |
15 |
310 |
|
1 x 95 |
1.1 |
1.5 |
17 |
404 |
|
1 x 120 |
1.2 |
1.5 |
18 |
490 |
|
1 x 150 |
1.4 |
1.6 |
20 |
603 |
|
1 x 185 |
1.6 |
1.7 |
23 |
748 |
|
1 x 240 |
1.7 |
1.8 |
26 |
954 |
|
1 x 300 |
1.8 |
1.8 |
28 |
1157 |
|
1 x 400 |
2.0 |
2.0 |
32 |
1478 |
|
1 x 500 |
2.2 |
2.1 |
36 |
1874 |
|
1 x 630 |
2.4 |
2.2 |
40 |
2382 |
Two-Core YJLV Dimensions and Weight
|
Conductor size (mm²) |
Insulation (mm) |
Sheath (mm) |
Approx. O.D. (mm) |
Approx. weight (kg/km) |
|
2 x 1.5 |
0.7 |
1.8 |
10 |
86 |
|
2 x 2.5 |
0.7 |
1.8 |
10 |
102 |
|
2 x 4 |
0.7 |
1.8 |
11 |
123 |
|
2 x 6 |
0.7 |
1.8 |
12 |
150 |
|
2 x 10 |
0.7 |
1.8 |
15 |
214 |
|
2 x 16 |
0.7 |
1.8 |
17 |
285 |
|
2 x 25 |
0.9 |
1.8 |
21 |
393 |
|
2 x 35 |
0.9 |
1.8 |
23 |
486 |
|
2 x 50 |
1.0 |
1.8 |
21 |
499 |
|
2 x 70 |
1.1 |
1.8 |
23 |
657 |
|
2 x 95 |
1.1 |
2.0 |
27 |
846 |
|
2 x 120 |
1.2 |
2.1 |
29 |
1058 |
|
2 x 150 |
1.4 |
2.2 |
32 |
1292 |
|
2 x 185 |
1.6 |
2.3 |
36 |
1583 |
Dimensions and weights are nominal reference values. Production tolerances and the selected conductor construction can result in small variations.